What does total alkalinity measure?
- The amount of dissolved calcium and magnesium
- The total of all dissolved solids in the water
- The water's ability to resist changes in pH
- The water's ability to conduct electric current
Show the answer
C. The water's ability to resist changes in pH
Alkalinity is the buffering capacity that holds pH steady when acids or bases are added. Dissolved calcium and magnesium are hardness, a different measurement.
Reference: PHTA Pool & Spa Operator Handbook, water balance chapter
Free chlorine holds steady at 2.0 ppm while the pH drifts from 7.2 up to 8.0. What happens to disinfection?
- It weakens, because less of the chlorine is HOCl
- It improves, because more of the chlorine is HOCl
- It is unchanged, because free chlorine is the same
- It stops, because chlorine cannot exist above 7.8
Show the answer
A. It weakens, because less of the chlorine is HOCl
As pH rises, hypochlorous acid converts to the much weaker hypochlorite ion, so the same free chlorine reading kills more slowly. The reading alone does not tell you how much is in the active form.
Reference: PHTA Pool & Spa Operator Handbook, disinfection chapter
Where is a vacuum gauge installed on a circulation system?
- On the suction side, just ahead of the pump
- On the discharge side, just after the pump
- On top of the filter tank at the air relief
- On the return line just before the inlets
Show the answer
A. On the suction side, just ahead of the pump
A vacuum gauge reads the suction the pump is pulling, so it sits on the suction side near the pump. The discharge side and the filter get pressure gauges.
Reference: PHTA Pool & Spa Operator Handbook, pumps and hydraulics